NGP 5050 smoke seal price and specs Beta

NGP's 5050 adhesive-mounted silicone bulb fire and smoke seal, sold in 17', 20', 21', 25' and 300' rolls (clear excepted from 300'). Pick a length and color and the part number assembles below.

Try:

Covers commercial door hardware, brand by brand ·

PricedNGP 5050 17'

How this part number assembles

ModelFire Smoke Seal
ColorCharcoalassumed
Length
Order as
5050C17'
Brand
NGP
Series
SMOKE & FIRE SEALS
$27.20
$Priced from the NGP price book · effective Jun 8, 2026 · pp. 22–23
How this price is built
Printed rate $1.60/ft × 17 ft$27.20
List price each$27.20

Every line is a printed value from the manufacturer's book — we add, never estimate.

Specifications

This configuration

Certifications and approvalsFire Smoke Seal (5050)BHMA Certified to ANSI/BHMA A156.22 Performance Tests for Heat, Cold, Adhesive and Energy Performance
Fire ratingFire Smoke Seal (5050)Edge Sealing System - Category G for 20 Minute Rated Category B Wood Doors Perimeter Application Up To: Single Swing 4'0 X 8'0 Pairs 8'0 X 8'0 Use 9800 at the Meeting Edge of Pairs
Size availabilityFire Smoke Seal (5050)Available in 17', 20', 21', 25' and 300'* Rolls
Smoke ratingFire Smoke Seal (5050)Smoke and Draft Control - Category H Up To 3 Hours Hollow Metal Fire Doors Up To 90 Minutes Wood Fire Doors Use 5070 at the Meeting Edge of Pairs

Series

AdhesiveModified acrylic pressure sensitive adhesive protected by release liner. Provides high initial adhesion and long-term holding power for permanent mounting in exterior or interior locations. Resistant to aging, weathering, UV radiation, water, detergent, alcohol and the influence of chemicals. End use temperature range, long term exposure -30°F up to 250°F. Shelf life of adhesive prior to installation is one year when stored at 75°F and 50% relative humidity or less.

From the catalog

STC SEAL SETS
Set printedRating printedPerimeter printedDoor bottom printedCorner pads printedThreshold
NGP Seal Sets maintain the static door panel STC with NO DROP OFF in an operable condition, up to the STC Rating indicated.
1335050 & 2525312V X 131N60FP8144S*
2455075 & 5060312V X 131N60FP8144S*
3525075 & 506012T6 X STC-FH60FP8144S*
4525075 & 5060423STC60FP8144S*
5525075 & 5060NoneNone896S-ADJ
8405075225NA or 335NA60FP8144S*
*optional
STC SEAL SETS
Set printedRating printedPerimeter printedDoor bottom printedCorner pads printedMeeting edge printedThreshold
6455075 & 5060423STC60FP (2 sets)5060 (2 req.)8144S*
7455075 & 506012T6 X STC-FH60FP (2 sets)5060 (2 req.)8144S*
*optional
PERIMETER AND DOOR BOTTOMS
Code printedDesc printed
107SPerimeter Seal
700SSeal at Head if a Parallel Arm Closer is Used
220SAutomatic Door Bottom (To Allow the Automatic Door Bottom to Properly Seal, Please Add a Threshold.)
MEETING EDGE OF PAIRS
Code printedDesc printed
109NOverlapping Astragal
115NAstragal Set
Category A Fire Doors
Statement printed
Hollow Metal Fire-Rated Doors and Wood Fire-Rated Doors constructed with edge seals built-in during the manufacturing process.
Require Category H – Smoke and Draft Control Gasketing at perimeter and at meeting edge of pairs of “S” label doors in corridor locations or smoke barrier walls.
Require Category H – Smoke and Draft Control door bottom seals on “S” label doors where pressurization is provided to restrict smoke movement (typically controlled by HVAC system).
The following products are recommended UL Classified Category H for wood doors - 90 min. max., hollow metal doors - 3 hour max.
Perimeter: 2525, 5020, 5040, 5050, 5070, 5075
Meeting edge of pairs: 115N, 125N, 137N, 137S, 5070, 9115, 9125, 9600, 9605
Category B Fire Doors
Statement printed
Wood Fire-Rated Doors that require the addition of a Category G classified edge sealing system in the field.
Require Category G – Edge Sealing System, at perimeter and at meeting edge of pairs.
Require Category H – Smoke and Draft Control Gasketing at perimeter and at meeting edge of pairs of “S” label doors in corridor locations or smoke barrier walls.
Require Category H – Smoke and Draft Control door bottom seals on “S” label doors where pressurization is provided to restrict smoke movement (typically controlled by HVAC system).
The following products are recommended UL Classified for both category G and H:
Perimeter 20 minute: 5050
Perimeter 45, 60, 90 minute: 9750
FAST ATTACH TWO-WAY TAPE
Statement printedCode printed
Fast Attach Two-Way Tape Provides an Easy and Effective Alternative for Gasketing Installation. Two-Way Tape is Applied to the Metal Housing Insuring a Quick and Easy Installation. 3 Tek-type Self-Drilling Screws are Provided to Further Secure Each Piece of Material to the Frame Stop. A No-Problem Installation With No Holes to Drill.
To Order Add Suffix “FATT” to Product Number. See Price List for Products Available With this Feature.FATT
FATT IS NOT CLASSIFIED FOR USE ON FIRE DOORS
SEAL FOR MULLION APPLICATIONS
Desc printed
Closed Cell Silicone Sponge Strip 1 1/8" Wide x 3/32" Thick With an Adhesive Strip for Mounting Directly to the Face of the Mullion That Doors Close Against
Self-Adhesive: See Adhesive Specifications on Page G14
CORNER PAD
Code printedDesc printed
54CPBlack Polypropylene Pile
Helps Acoustics and Seals Corner Gap for Air Leakage Control. Apply to Jamb on Hinge Side, Opposite Bottom Corner of Door Edge.
Self-Adhesive: See Adhesive Specifications on Page G14
Code printedColor printed
5050CCharcoal
Clear Not Available in 300' Rolls
Meets Requirements of RoHS Directive
See Adhesive Specifications on Page G14
STC 33
Code printedColor printed
Ligature-Resistant Feature has Serrations Every 8" Designed to Break Apart, Preventing it From Being Used to Hang or Strangle
Applications Include Psychiatric Facilities, Prisons and Other Treatment Facilities
Installs as a Continuous Length Providing the Same Sealing Properties for Light, Sound, Air and Smoke as Our Original 5050
ANTI-LIG 5050CCharcoal
Meets Requirements of RoHS Directive
See Adhesive Specifications on Page G14
Code printedColor printed
2525CCharcoal
STC 33
Code printedColor printed
5040CCharcoal
Code printedColor printed
5060CCharcoal
STC 52
Property printed
Self-Adhesive Silicone Rubber
Good Abrasion Resistance
BHMA Certified to ANSI/BHMA A156.22 Performance Tests for Heat, Cold, Adhesive and Energy Performance
Adhesive Specifications Shown on Page G14
Code printedColor printed
*White Only Available in 17' Rolls
**Clear Unavailable in 300' Rolls
5075CCharcoal
STC 52
Property printed
Self-Adhesive Silicone Rubber
Good Abrasion Resistance
Moisture-Resistant
BHMA Certified to ANSI/BHMA A156.22 Performance Tests for Heat, Cold, Adhesive and Energy Performance
Flame-Resistant
REACH and RoHS Compliant
Adhesive Specifications Shown on Page G14
Code printedColor printed
5020CCharcoal
Color printed
1/8" Clearance Required Between Door and Frame
Self-Adhesive: See Adhesive Specifications on Page G14
NGP-EDGE SEALING SYSTEM
Statement printed
NGP Intumescent Materials are Formulated to Expand at 375°F to 400°F up to 8-10 Times Their Original Thickness, Completely Sealing the Gap Around and Between Doors During a Fire.
INTUMESCENT FIRE SEAL
Code printedColor printed
Meeting Edge Application Up To 8'0 X 9'0 Pairs of Category B Wood Doors:
20 Minute Rated with Single Strip Installed
45, 60 Minute Rated with Two Strips Installed
Intumescent With Protective Skin
Self-Adhesive: See Adhesive Specifications on Page G14
9800GRGray
9800CCharcoal
Code printedNote printed
9600A
9600A-BB
9600B
9600DKB
Order as Set to Receive Two Pieces

6E20F05B-0FC1-4B42-A833270F8EA30BD9 · 2026-08

That's one line. Conversant prices whole schedules — hundreds of lines, minutes.

Frequently asked questions

How much does NGP 5050 smoke seal cost?

The 5050 sells by the roll — 17', 20', 21', 25' and 300' lengths are printed, with clear not available in 300' rolls. Pick a roll length and color above and the page prices it live from the current NGP price book.

What colors does the NGP 5050 come in?

Four printed colorways: brown (5050B), charcoal (5050C), white (5050W) and clear (5050CL).

Is the 5050 fire rated?

NGP prints the 5050 as a Category G edge sealing system for 20 minute rated Category B wood doors — perimeter application up to 4'0 x 8'0 single swing and 8'0 x 8'0 pairs — and as Category H smoke and draft control up to 3 hours on hollow metal fire doors and up to 90 minutes on wood fire doors.

What goes at the meeting edge on pairs of doors?

The 5050 card names a companion seal for the meeting edge of pairs: 9800 for the Category G edge-sealing application and 5070 for Category H smoke and draft control.

How does the 5050 attach to the frame?

It is self-adhesive silicone: NGP specifies a modified acrylic pressure sensitive adhesive protected by a release liner, rated for long-term exposure from -30°F up to 250°F, with a one-year shelf life prior to installation when stored at 75°F and 50% relative humidity or less.

Does the 5050 carry an acoustic rating?

The 5050 card prints STC 33. It also appears in one of the eight printed STC seal sets — set 1 of the single-doors table, pairing 5050 & 2525 perimeter seals at a rating of 33. NGP states its seal sets maintain the static door panel STC with no drop off in an operable condition, up to the STC Rating indicated.

Is the NGP 5050 BHMA certified?

Yes — the card prints BHMA certification to ANSI/BHMA A156.22 performance tests for heat, cold, adhesive and energy performance, and states the seal meets the requirements of the RoHS directive.