Specifications
Series
From the catalog
| Spec | L Mechanical & L Wired Electrified | LM9300 |
|---|---|---|
| Case material | Cold Rolled Steel (CRS) with zinc dichromate plating | Cold Rolled Steel (CRS) with zinc dichromate plating |
| Case size | L9000 Series: 4-7⁄16" x 6-1⁄16" x 1" (113 mm x 154 mm x 25 mm) L400 Series: 4-7⁄16" x 3-5⁄8" x 1" (113 mm x 92 mm x 25 mm) | 4-7⁄16" x 6-1⁄16" x 1" (113 mm x 154 mm x 25 mm) |
| Spacing | Knob or lever to cylinder: 3-7⁄8" (98 mm); knob or lever to thumbturn hub: 2-11⁄16" (68 mm) | Knob or lever to cylinder: 3-7⁄8" (98 mm); knob or lever to thumbturn hub: 2-11⁄16" (68 mm) |
| Door thickness | Standard: 1-3⁄4" (44 mm) Optional: 1-3⁄8" (35 mm) Over 1-3⁄4" specify door thickness and position in door EE, EI, EO, ED | Standard: 1-3⁄4" (44 mm) |
| Backset | 2-3⁄4" (70 mm) only | 2-3⁄4" (70 mm) only |
| Handing | L9000 Series: Field-reversible L400 Series: Non-handed | Handed to order, not field reversible |
| Spec | L Mechanical & L Wired Electrified | LM9300 |
|---|---|---|
| Levers/knobs | 33 lever designs (see pages 10-13): Forged brass and cast stainless steel Two knob designs (see page 13): Heavy-duty wrought brass or stainless steel (not available for LM9200) Tactile warning applied to outside lever; available on 01, 02, 03, 05, 06, 07, 12, 17, 18, M51, M52, M81, ME1, ME2, ME3 lever designs | 33 lever designs (see pages 10-13): Forged brass and cast stainless steel Two knob designs (see page 13): Heavy-duty wrought brass or stainless steel (not available for LM9200) Tactile warning applied to outside lever; available on 01, 02, 03, 05, 06, 07, 12, 17, 18, M51, M52, M81, ME1, ME2, ME3 lever designs |
| Health care trims | Ligature resistant lever (SL1) and knob (SK1) High Security Ligature Resistant (HSLR) trim HL6 hospital latch | — |
| Roses/escutcheons | L escutcheons: 7-15⁄16” x 1-3⁄4” x 7⁄16” (202 mm x 44 mm x 11 mm); cold-forged brass and stainless steel N escutcheons: 7-7⁄8” x 2-1⁄2” x 7⁄16” (200 mm x 64 mm x 11 mm); heavy-wrought, reinforced brass and stainless steel Roses: A, B, C: wrought brass and stainless steel; AVA and MER: forged brass | L escutcheons: 7-15⁄16” x 1-3⁄4” x 7⁄16” (202 mm x 44 mm x 11 mm); cold-forged brass and stainless steel N escutcheons: 7-7⁄8” x 2-1⁄2” x 7⁄16” (200 mm x 64 mm x 11 mm); heavy-wrought, reinforced brass and stainless steel Roses: A, B, C: wrought brass and stainless steel; AVA and MER: forged brass |
| Finishes | 14 available: 605, 606, 609, 612, 613, 619, 622, 625, 626, 626AM, 629, 630, 630AM, 643e | 14 available: 605, 606, 609, 612, 613, 619, 622, 625, 626, 626AM, 629, 630, 630AM, 643e |
| Combinations | Combinations of available levers and/or knobs allowed. Roses cannot be combined with escutcheons. | Combinations of available levers and/or knobs allowed. Roses cannot be combined with escutcheons. |
| Spec | L Mechanical & L Wired Electrified | LM9300 |
|---|---|---|
| Armor | L9000 Series Standard: 1-1⁄4" x 8" x 7⁄32" (32 mm x 203 mm x 6 mm) Optional: 1-1⁄16" x 8" x 7⁄32" (27 mm x 203 mm x 6 mm) L400 Series 1-1⁄4” x 5-9⁄16” x 7⁄32" (32 mm x 141 mm x 6 mm) | Standard: 1-1⁄4" x 8" x 7⁄32" (32 mm x 203 mm x 6 mm) Optional: 1-1⁄16" x 8" x 7⁄32" (27 mm x 203 mm x 6 mm) |
| Latch | 3⁄4" (19 mm) throw stainless steel latch with anti-friction tongue | 3⁄4" (19 mm) throw stainless steel latches, top and bottom latches via concealed vertical rod |
| Deadbolt | 1" (25 mm) throw stainless steel deadbolt | — |
| Strike | L9000 Series Standard: ANSI curved lip strike 1-1⁄4" x 4-7⁄8" (32 mm x 124 mm) x 1-3⁄16" (30 mm) lip length with dust box Optional: Extended lip strike options (7⁄8", 1", 1-1⁄2", 1-3⁄4", 2") L400 Series Standard: 1-1⁄8" x 3-1⁄2" (29 mm x 89 mm) with dust box Optional: 1-1⁄4" x 4-7⁄8" (32 mm x 124 mm) with dust box | Standard: ANSI curved lip strike 1-1⁄4" x 4-7⁄8" (32 mm x 124 mm) x 1-3⁄16" (30 mm) lip length with dust box Optional: Extended lip strike options (7⁄8", 1", 1-1⁄2", 1-3⁄4", 2") |
| Spec | L Mechanical & L Wired Electrified | LM9300 |
|---|---|---|
| Formats | 6-pin Conventional mortise cylinder (standard); also available in concealed mortise cylinder, FSIC, SFIC and 7-pin SL cylinder formats plus less cylinder options; two nickel silver cut keys per lock; compatible with competitor cylinders and cams that support the L9000 Series | 6-pin Conventional mortise cylinder (standard); also available in concealed mortise cylinder, FSIC, SFIC and 7-pin SL cylinder formats plus less cylinder options; two nickel silver cut keys per lock; compatible with competitor cylinders and cams that support the L9000 Series |
| Keyways | Patented Everest 29 S123 (standard); also available in open, restricted, and Primus security levels with available master keying and construction keying | Patented Everest 29 S123 (standard); also available in open, restricted, and Primus security levels with available master keying and construction keying |
| Spec | L Mechanical & L Wired Electrified | LM9300 |
|---|---|---|
| Input voltage | 12V or 24V DC (24V DC only on motorized latch retraction functions) | — |
| Operating mode | Fail Safe or Fail Secure via switch on chassis (except L9510, L9580, and L9582) | — |
| Peak current | 12V operating voltage: 1 amp (not applicable to latch retraction functions) 24V operating voltage: 0.4 amp lever control; 1.4 amp latch retraction Holding current: 0.1 amp lever control; 0.1 amp latch retraction | 12V operating voltage: 1 amp (not applicable to latch retraction functions) 24V operating voltage: 0.4 amp lever control; 1.4 amp latch retraction Holding current: 0.1 amp lever control; 0.1 amp latch retraction |
| Request to exit | Modular option on L909X, L949X, L9510, L9580, L9692, and L9695 electrified functions (when ordering or added in field) Available for mechanical functions: L9010/25/26/50/56/70/71/80 and L9453/56/58/65/66/80/85/96 Rating: 3A @ 125V AC/2A @ 30V DC | — |
| Latch bolt monitor | Available on all electrified functions and L9010/25/26/50/56/70/71/80/82 and L9453/56/65/66/80/85/96 mechanical functions | — |
| Door position sensor | Internal available on L909x electrified and L9010/25/26/80/82 mechanical functions; external available on all functions | — |
| Deadbolt monitor | Standard on L949x electrified and available on L9453/56/57/58/80/85/96 mechanical functions | — |
| L Mechanical & L Wired Electrified | LM9300 |
|---|---|
| 10-year limited mechanical and 3-year limited electromechanical | 3-year limited mechanical |
| Spec | L Mechanical & L Wired Electrified | LM9300 |
|---|---|---|
| ANSI/BHMA | L/LV9000: ANSI/BHMA A156.13-2017 Series 1000, Grade 1 Operational and Security With FSIC Interchangeable Core Cylinders: Grade 1 Operational, Grade 2 Security With SFIC Interchangeable Core Cylinders: Grade 1 Operational, Grade 3 Security L400: ANSI/BHMA A156.36-2010, Grade 1 | ANSI/BHMA A156.37-2014 Grade 1 Operational and Security With FSIC Interchangeable Core Cylinders: Grade 1 Operational, Grade 2 Security With SFIC Interchangeable Core Cylinders: Grade 1 Operational, Grade 3 Security |
| ICC | Complies with ICC A117.1 Accessible and Usable Buildings and Facilities | Certified by Intertek and labeled showing compliance to ICC 500-2020, FEMA P-320 (2021), and FEMA P-361 (2021) as required by the International Building Code and Florida Building Code Enhanced Protection Area (EHPA) standard when paired with appropriate Steelcraft doors (all except LM9310 and LM9370 functions) |
| UL/cUL | L/LV9000 Series: UL 10C and CAN/ULC-S104 3-hour fire door (except L9076 and L9077) Electrified functions are UL/ULC listed 3-hour for single-point locking applications UL 437 Listed when using UL 437 Primus cylinder L400 Series: L400 UL Listed Auxiliary Lock for 3-hour fire door UL 437 Listed when using UL 437 Primus cylinder | UL 10C and CAN/ULC-S104 3-hour fire door UL 437 Listed when using UL 437 Primus cylinder |
| UL 294 | UL 294 Access Control Performance Levels: Destructive Attack - level I; Line Security - level I; Standby Power - level I; Endurance - level IV (with DM or LX, Endurance - level I) ULC-S319 Class III (L909X and L949X functions only) | — |
| CA Fire Code | All levers with a return to door of 1⁄2" (13 mm) or less comply (Formerly Title 19, California State Fire Marshal Standard) | All levers with a return to door of 1⁄2" (13 mm) or less comply (Formerly Title 19, California State Fire Marshal Standard) |
| Building codes | Miami-Dade NOA and Florida Building Commission Listings Texas Department of Insurance (TDI) for impact and non-impact applications | Florida Building Commission Listing for impact rated assemblies |
| Federal | BAA compliant, all functions | BAA compliant, all functions |
| Schlage | Code printed | ANSI | Name printed |
|---|---|---|---|
| L/LV9040 with XL11-446 | L/LV9040 | - | Privacy with thumbturn both sides |
| Schlage | ANSI | Name printed |
|---|---|---|
| L/LV9050 | F04 | Entrance/office lock |
| Schlage | Code printed | ANSI | Name printed |
|---|---|---|---|
| L9460 with XL11-635 | L9460 | - | Cylinder x thumbturn deadbolt with fixed levers |
| L9460 with XL11-886 | L9460 | - | Cylinder x thumbturn deadbolt with inside active lever |
| L9464 with XL11-886 | L9464 | - | Single cylinder deadbolt with inside active lever |
| L9485 with XL11-557 | L9485 | - | Prison function lock |
| Schlage | Code printed | ANSI | Name printed |
|---|---|---|---|
| L9462 with XL11-886 | L9462 | - | Double cylinder deadbolt with active inside lever |
| Code printed | Format printed |
|---|---|
| P6 | 6-pin cylinder (default) |
| T | FSIC – Construction Core |
| F | FSIC, 6-pin less Schlage logo |
| T | Refundable Construction FSIC |
| Code printed | Name printed |
|---|---|
| RX | Request to Exit |
| LX | Latch bolt monitor |
| DPS | Door Position Switch |
| DM | Deadbolt monitor (DM) |